Why seismic checks matter in soil nail wall design


An illustrated SnailPLUS case study | 10 m excavation | seven nail rows | static and pseudo-static seismic analyses


Beyond static stability

A soil-nailed excavation can satisfy its permanent-condition stability criteria and still experience a significant increase in reinforcement demand during an earthquake. Pseudo-static seismic assessment provides a practical screening check where seismic action is relevant to the site. It should accompany, rather than replace, checks on nail resistance, connections, facing and potential permanent deformation [1, 2].


Excavation sequence and model

The example considers progressive excavation to approximately 10 m, with seven rows of soil nails installed as the excavation advances. The screenshots below illustrate selected stages; the full model contains eight calculated stages, including the final and seismic conditions. Soil nail lengths and positions vary with depth, as shown in the source model


Selected construction stages from SnailPLUS (user-provided model screenshots).
Figure 1. Selected construction stages from SnailPLUS (user-provided model screenshots).

Ground profile and seismic inputs

The user-provided analysis contains a sloping ground profile and four soil units. The upper soils have friction angles of 30° and 34°, while the underlying undrained material has Su = 71.8 kPa; the deeper layer is modelled with c′ = 10 kPa and φ′ = 36°. The seismic condition uses horizontal and vertical coefficients kh = 0.15 and kv = 0.015. These are example input assumptions, not site-specific recommendations.


 

Static versus seismic analysis

Both cases use the Morgenstern–Price limit equilibrium method with an automatic slip-surface search. The specified minimum overall factors of safety are 1.50 for the permanent long-term condition and 1.10 for the seismic extreme-event condition. These match commonly cited FHWA recommendations for the relevant design context, subject to the owner’s requirements and deformation assumptions [1].


Permanent long-term condition: calculated global FS = 1.611 (SnailPLUS screenshot).
Figure 2. Permanent long-term condition: calculated global FS = 1.611 (SnailPLUS screenshot).

Extreme-event pseudo-static condition: calculated global FS = 1.323 (SnailPLUS screenshot).
Figure 3. Extreme-event pseudo-static condition: calculated global FS = 1.323 (SnailPLUS screenshot).

What changed when seismic loading was included?

Output

Permanent

Seismic

Required overall FS

1.50

1.10

Calculated overall FS

1.611

1.323

Maximum nail force

43.2 kN

53.4 kN

Maximum nail-head force

30.2 kN

37.4 kN

Maximum nail structural utilisation (STR)

0.117

0.102

Maximum plate utilisation (STR)

0.454

0.430

Maximum facing utilisation (STR)

0.046

0.057


The global factor of safety falls by about 18%, while the maximum reported nail force rises by about 24%. Both analyses satisfy the minimum FS assigned to their respective design conditions. The maximum values in each column are model-wide outputs, not necessarily forces from the same nail or the same location.


Importantly, the peak structural utilisation ratios do not all increase in the seismic case. They reflect the respective design checks, including the applicable design factors and resistance definitions, and should not be interpreted as direct proxies for force demand.


SnailPLUS stage-by-stage summary: overall FS, maximum nail forces and selected structural utilisation ratios.
Figure 4. SnailPLUS stage-by-stage summary: overall FS, maximum nail forces and selected structural utilisation ratios.

Practical engineering implications

A global stability result alone cannot establish the adequacy of a soil nail wall. The engineer should also check tensile resistance and pullout, local nail–head and plate demands, facing bending and punching, and whether the seismic load case changes the governing mechanism. Pseudo-static calculations do not explicitly predict accumulated earthquake-induced displacement or cyclic degradation; where these control the project, a deformation-based or more advanced dynamic assessment may be needed [1, 2].


Conclusion

This example illustrates the value of comparing permanent and extreme-event loading during soil nail wall design. A static FS of 1.611 would not reveal the subsequent reduction to 1.323 or the higher maximum nail force obtained under the assumed pseudo-static action. SnailPLUS brings staged construction, limit equilibrium analysis and reinforcement checks together, allowing those changes to be investigated within one model [3].


References

[1] FHWA (2015). Soil Nail Walls Reference Manual. Geotechnical Engineering Circular No. 7, FHWA-NHI-14-007. https://rosap.ntl.bts.gov/view/dot/40556

[2] FHWA (2011). LRFD Seismic Analysis and Design of Transportation Geotechnical Features and Structural Foundations. FHWA-NHI-11-032. https://highways.dot.gov/sites/fhwa.dot.gov/files/FHWA-NHI-11-032.pdf

[3] Deep Excavation LLC. SnailPLUS – Soil Nail Walls Design (product documentation). https://www.deepexcavation.com/products/snail-plus-soil-nailing-software